• 0750 274 1000 or 0750 275 1000
  • Contact Us
  • MG Construction
  • Our Company
  • Terms of Use
MG GroupMG Group
  • Home
  • Services
    • Provision of Specialists
    • Medical Tourism
    • Medical Education
    • Our Doctors
  • Products
  • Clients
  • Activities
  • About
    • MG Medical
    • MG Group
    • Careers
WhatsApp

Distal Medial Tibial Plates Angularly Stable

Kristoffer2021-12-12T12:18:33+03:00
Orthopedic Comments Off on Distal Medial Tibial Plates Angularly Stable
2560665

Distal Medial Tibial Plates Angularly Stable

  • Product Overview
  • Documents & Description
  • How to request

Product Overview

Product Description

The plate is used for fixation of distal tibia fracture parts. Angularly stable screws are mainly used at articular fractures. The angles of the screws introductions are chosen in a way so that they would fix as many fragments as possible and they would minimise the possibility of screws pulling out of the bone. The distal part of the plate is the same at all the sizes, there are 10 holes for locking screws. The shank part has from 2 to 12 holes and 1 oval hole. The longer plates enable fixation in the area of diaphysis.

The plates are anatomically shaped and are supplied in right or left version.

To these angularly stable plates are used self-tapping locking screws with diameters 3,5 mm and 3,5/2,7 mm.

Implants are made of implant steel ISO 58321E or Titanium Ti6Al4V ELI ISO 5832-3.

Angularly stable plates

The system is based on the principle of the inner fixator. By means of the tight connection “screw-plate”, the angularly stable connection is achieved between the plate and the bone. This transfers part of the weight from the screw-bone connection to the screw-plate connection. Thanks to that it is possible to use the system successfully even in a less quality and an osteoporotic bone.

If the angularly stable plate is used with locking bone screws, the plate and the screws make tight system together. The plate does not have to be pushed against the bone therefore the bone still gets sufficient supply of the blood. Locking bone screws can be introduced monocortically without enfeebling the strength of the configuration or the fracture fixation, because the screws are firmly anchored in the plate.

Documents & Description

Click here to see  The Ordering Information


How to request

If you are interested in this product,

Call Us Now

OR

Send Us An Email

M.G. Branches

  • Construction & Design
  • Educational Services
  • Medical Supplies
  • Medical Services

Quick Links

  • About Us
  • Product Categories
  • Upcoming Events
  • Contact Us
  • Terms of Use

Contact Information

  • Address: Italian city 1,house #75,100m Road,Erbil-Iraq
  • Phone: +964 750 274 1000
  • Email: info@mg-group.co
  • Working Days/Hours: Sat - Thur / 10:00 AM - 6:00 PM
MG Group © Copyright 2018. All Rights Reserved.
  • Home
  • Services
    • Provision of Specialists
    • Medical Tourism
    • Medical Education
    • Our Doctors
  • Products
  • Clients
  • Activities
  • About
    • MG Medical
    • MG Group
    • Careers
  • Contact Us
  • MG Construction
  • Our Company
  • Terms of Use
WhatsApp